MIB Parameters
Table D-2: Private MIB Parameters (Sheet 14 of 18)
Name
winlink1000OduAgnLastEventsIfIndex
winlink1000OduAgnLastEventsTimeT
winlink1000OduAgnLastEventsText
winlink1000IduAdmProductType
winlink1000IduAdmHwRev
winlink1000IduAdmSwRev
winlink1000OduAdmNumOfExternalAlarmIn
winlink1000OduAdmExternAlarmInTable
winlink1000OduAdmExternAlarmInEntry
winlink1000OduAdmExternAlarmInIndex
winlink1000OduAdmExternAlarmInText
winlink1000OduAdmExternAlarmInAdminState 1.3.6.1.4.1.4458.1000.2.1.5.1.3
winlink1000OduAdmExternAlarmInStatus
winlink1000IduAdmSN
winlink1000IduAdmIduDetectionMode
winlink1000IduAdmMountedTrunks
winlink1000IduAdmLicensedTrunks
winlink1000IduAdmVlanSupported
winlink1000IduAdmVlanEgressMode
winlink1000IduAdmVlanIngressMode
winlink1000IduAdmVlanDefaultPortVIDs
winlink1000IduAdmVlanLan1UntaggedVIDs
winlink1000IduAdmVlanLan2UntaggedVIDs
winlink1000IduAdmVlanSfpUntaggedVIDs
winlink1000IduAdmVlanLan1FilteredVIDs
winlink1000IduAdmVlanLan2FilteredVIDs
winlink1000IduAdmVlanSfpFilteredVIDs
winlink1000IduSrvDesiredTrunks
WinLink 1000 User Manual
OID
1.3.6.1.4.1.4458.1000.1.7.4.2.1.3
1.3.6.1.4.1.4458.1000.1.7.4.2.1.4
1.3.6.1.4.1.4458.1000.1.7.4.2.1.5
1.3.6.1.4.1.4458.1000.2.1.1
1.3.6.1.4.1.4458.1000.2.1.2
1.3.6.1.4.1.4458.1000.2.1.3
1.3.6.1.4.1.4458.1000.2.1.4
1.3.6.1.4.1.4458.1000.2.1.5.1.1
1.3.6.1.4.1.4458.1000.2.1.5.1.2
1.3.6.1.4.1.4458.1000.2.1.5.1.4
1.3.6.1.4.1.4458.1000.2.1.6
1.3.6.1.4.1.4458.1000.2.1.7
1.3.6.1.4.1.4458.1000.2.1.8
1.3.6.1.4.1.4458.1000.2.1.9
1.3.6.1.4.1.4458.1000.2.1.10
1.3.6.1.4.1.4458.1000.2.1.11
1.3.6.1.4.1.4458.1000.2.1.12
1.3.6.1.4.1.4458.1000.2.1.13
1.3.6.1.4.1.4458.1000.2.1.14
1.3.6.1.4.1.4458.1000.2.1.15
1.3.6.1.4.1.4458.1000.2.1.16
1.3.6.1.4.1.4458.1000.2.1.17
1.3.6.1.4.1.4458.1000.2.1.18
1.3.6.1.4.1.4458.1000.2.1.19
1.3.6.1.4.1.4458.1000.2.2.2
Release 1.9.40
Type
Description
Integer
RO
Interface Index where the event occurred. Traps
that are
will have the following value: 65535.
Integer
RO
Timestamp of this trap. This number is in seconds
from Midnight January 1st 1970.
DisplayString
RO
Trap display text (same as the text in the sent
trap).
DisplayString
RO
IDU configuration description.
DisplayString
RO
IDU Hardware Revision.
DisplayString
RO
IDU Software Revision.
Integer
RO
Indicates the number of currently available
External Alarm Inputs.
N/A This is the External Alarm Inputs table.
N/A Entry containing the elements of a single External
Alarm Input.
winlink1000OduAdmExternAlarmInIndex}
Integer
RO
This value indicates the index of the External
Alarm Input entry.
DisplayString
RW This field describes the External Alarm Input. It is
an optional string of no more than 64 characters
which will be used in the event being sent as a
result of a change in the status of the External
Alarm Input. DEFVAL {Alarm Description}
Integer
RW This value indicates if this External Alarm Input is
enabled or disabled.
Integer
RO
This value indicates the current status of the
External Alarm Input.
DisplayString
RO
IDU Serial Number
Integer
RW The parameter defines whether to send Ethernet
frames to detect an IDU.
values are: userDisabled (3) userEnabled (4).
change requires a reset and is effective after reset.
Integer
RO
Number of mounted trunks in the IDU
Integer
RO
Number of Licensed Trunks in the IDU
Integer
RO
Identifies if the local IDU supports VLAN tag/untag
DisplayString
RW VLAN tag/untag egress values
DisplayString
RW VLAN tag/untag ingress values
DisplayString
RW VLAN tag/untag default VLAN ids for each port -
Right most digit is Vlan priority (0-6) other digits
compose Vlan Id (1-4094)
DisplayString
RW VLAN untagged VIDs for LAN1 port
DisplayString
RW VLAN untagged VIDs for LAN2 port
DisplayString
RW VLAN untagged VIDs for Sfp port
DisplayString
RW VLAN filtered VIDs for LAN1 port
DisplayString
RW VLAN filtered VIDs for LAN2 port
DisplayString
RW VLAN filtered VIDs for Sfp port
Integer
RW Required trunks bitmap.
possible trunks that can be configured may vary
based on the IDU hardware
selected air interface rate and the range of the
installation.
enables the user to select only available
configurations. A change is effective immediately
if applied to a master unit and the link is in service
mode.