MIB Parameters
Table D-2: Private MIB Parameters (Sheet 17 of 18)
Name
winlink1000IduTdmCurrentTxClock
winlink1000IduTdmCurrentBlocksHigh
winlink1000IduTdmRemoteQual
winlink1000IduTdmRemoteQualEval
winlink1000IduTdmSrvEval
winlink1000IduTdmBackupAvailableLinks
winlink1000IduTdmBackupTable
winlink1000IduTdmBackupEntry
winlink1000IduTdmBackupIndex
winlink1000IduTdmBackupMode
winlink1000IduTdmBackupCurrentActiveLink
winlink1000IduTdmJitterBufferSize
winlink1000IduTdmJitterBufferDefaultSize
winlink1000IduTdmJitterBufferMinSize
winlink1000IduTdmJitterBufferMaxSize
winlink1000IduTdmJitterBufferSizeEval
winlink1000IduTdmType
winlink1000IduTdmTypeEval
winlink1000IduTdmLineStatusStr
winlink1000IduTdmHotStandbySupport
winlink1000IduTdmDesiredHotStandbyMode
winlink1000IduTdmHotStandbyOperationStatu
s
winlink1000IduTdmBackupLinkConfiguration
winlink1000GeneralTrapDescription
winlink1000GeneralTrapSeverity
winlink1000GeneralCookie
winlink1000GeneralEcChangesCounter
WinLink 1000 User Manual
OID
1.3.6.1.4.1.4458.1000.2.6.7.1.103
1.3.6.1.4.1.4458.1000.2.6.7.1.104
1.3.6.1.4.1.4458.1000.2.6.8
1.3.6.1.4.1.4458.1000.2.6.9
1.3.6.1.4.1.4458.1000.2.6.10
1.3.6.1.4.1.4458.1000.2.6.11
1.3.6.1.4.1.4458.1000.2.6.12.1.1
1.3.6.1.4.1.4458.1000.2.6.12.1.2
1.3.6.1.4.1.4458.1000.2.6.12.1.3
1.3.6.1.4.1.4458.1000.2.6.13
1.3.6.1.4.1.4458.1000.2.6.14
1.3.6.1.4.1.4458.1000.2.6.15
1.3.6.1.4.1.4458.1000.2.6.16
1.3.6.1.4.1.4458.1000.2.6.17
1.3.6.1.4.1.4458.1000.2.6.18
1.3.6.1.4.1.4458.1000.2.6.19
1.3.6.1.4.1.4458.1000.2.6.20
1.3.6.1.4.1.4458.1000.2.6.21
1.3.6.1.4.1.4458.1000.2.6.22
1.3.6.1.4.1.4458.1000.2.6.23
1.3.6.1.4.1.4458.1000.2.6.24
1.3.6.1.4.1.4458.1000.100.1
1.3.6.1.4.1.4458.1000.100.2
1.3.6.1.4.1.4458.1000.100.3
1.3.6.1.4.1.4458.1000.100.4
Release 1.9.40
Type
Description
Integer
RW TDM Transmit Clock. A change is effective after
re-activation of the TDM service.
Counter
RO
High part of the 64 bits counter Current Blocks
Integer
RO
Estimated average interval between error second
events.
value of -1 is used to indicate an undefined state.
Integer
RO
Estimated average interval between error second
events during evaluation process. The valid
values are 1-2^31 where a value of -1 is used to
indicate an undefined state.
Integer
RW Evaluated TDM service bit mask. Setting this
parameter to value that is bigger than the activated
TDM service bit mask will execute the evaluation
process for 30 seconds. Setting this parameter to
0 will stop the evaluation process immediately.
Integer
RO
Number of TDM backup trunks.
N/A IDU TDM Links Statistics table.
N/A IDU TDM Links Statistics table entry. INDEX {
winlink1000IduTdmBackupIndex }
Integer
RO
Table index.
Integer
RW TDM backup mode: Enable or Disable where the
main link is the air link or the external link.
Changes will be effective immediatly.
Integer
RO
TDM backup current active link: N/A
active or external link is active.
Integer
RW TDM Jitter Buffer Size.
between the minimum and the maximum TDM
Jitter Buffer Size.
millisecond.
Integer
RO
TDM Jitter Buffer Default Size. The units are 0.1 x
millisecond.
Integer
RO
TDM Jitter Buffer Minimum Size. The units are 0.1
x millisecond.
Integer
RO
TDM Jitter Buffer Maximum Size. The units are 0.1
x millisecond.
Integer
RW TDM Jitter Buffer Size for evaluation.
must be between the minimum and the maximum
TDM Jitter Buffer Size.
millisecond.
Integer
RW TDM Type (The value undefined is read-only).
Integer
RW TDM Type for evaluation.
DisplayString
RO
Line status.
Integer
RO
Indicates if Hot Standby is supported.
Integer
RW Desired Hot Standby Mode.
Integer
RO
The Link Actual Status.
Integer
RW The current configuration of the backup link.
DisplayString
RO
Trap's Description. Used for Trap parameters.
Integer
RO
Trap's Severity. Used for Trap parameters.
DisplayString
RW Reserved for the Manager application provided
with the product used for saving user preferences
affecting ODU operation.
Integer
RO
This counter is initialized to 0 after a device reset
and is incremented upon each element constant
write operation via SNMP or Telnet.
Appendix D
The valid values are 1-2^31 where a
air link is
The value must be
The units are 0.1 x
The value
The units are 0.1 x
D-22

Advertisement