Other Advanced Preferences

Other Advanced Preferences

Setting the RADWIN Manager Language

In the dialog of
Figure
other localizations are available.

Setting SNMP Parameters

Use these choices to set the SNMP monitoring interval and time-out. These are only signifi-
cant if you are using an SNMP based network management system.

Remote Power Fail Indication

Remote power fail indication indicates to one side that the other side has suffered a power
failure. The failed site sends a final trap indication about the power loss just before powering
off.
A "Dying-Gasp" circuit identifies the power failure at a minimum interval of 20 milliseconds
before the ODU or IDU powers off. During that interval a message notifying the power failure
is sent to opposite site. External alarm output number 4 indicates power failure at the oppo-
site site.

Troubleshooting

Use the following table to troubleshoot LED fault indications:
Table 9-7: LED fault indicators
LED
Status
PWR
Off
IDU
Red
ODU
Red
Orange
AIR I/F
Red
Orange
SVC
Red
Off
Red
Orange
HSS
Red
STBY
Orange
WinLink 1000 User Manual
9-20, you can set the RADWIN Manager interface language, where
Remedy
Check that power is connected to the IDU
Check that the IDU/ODU cable is properly wired and connected.
Check that the IDU/ODU cable is properly wired and connected.
Complete the installation procedure from the RADWIN Manager
Check the antenna alignment. Check that the radio configuration of both site A and
site B units are the same (Channel and Link ID).
Alarm detected at the Site B interface or Local or Remote loopback
Alarm detected at the Site A interface
Ethernet only IDU or E1/T1 not configured
HSS not operational due to improper signal detection. This ODU is not transmitting
HSS is operational. One of the following conditions apply:
This ODU is a master that is generating signals and detecting signals
This ODU is a master that is generating signals but detected improper sig-
nals
This ODU is a client "Continue Tx" but is not detecting signals
This ODU is a client "Disable Tx" and is detecting signals from multiple
sources
All orange cases transmit.
MHS mode Primary, Link state not active
MHS mode Secondary, Link state active
Release 1.9.40
Chapter 9
9-19