Chapter 3 Configuration
The Evaluate button becomes enabled when a new rate has been
Note
selected.
11. A question box pops up, asking if you want to re-evaluate the link.
Click Yes to change the rate or No to keep the existing rate.
12. Click Next.

Configuring Service Parameters

In the Service Parameters dialog box configure E1/T1 (x1 or x2) and
Ethernet parameters.
To configure E1/T1 and Ethernet:
1. In the Service dialog box, select one of the following:
3-10
Performing Configuration of WinLink 1000
Selecting a new air-interface rate causes the system to change
its air-interface rate and commence evaluation of the link
performance at the new air-interface rate. This process of
evaluation takes a few seconds.
The Service Parameters dialog box appears.
E1/T1 – Select the E1/T1 field, if you intend to transmit E1/T1
data and Ethernet data.
The Ethernet BW field shows the remaining bandwidth in Mbps
available for Ethernet. The available bandwidth depends on the
number of E1/T1 ports selected.
Select the Ethernet field, if you intend to transmit Ethernet data
only