System Operation Description; Figure 12-12 Secondary - Radwin WinLink 1000 User Manual

Broadband wireless
Hide thumbs Also See for WinLink 1000:
Table of Contents

Advertisement

System Operation description

Figure 12-12: Secondary Link operating after the switch back to Primary
System Operation description
Normal operation
Switching to backup
Backup operation
Switching back to
primary
WinLink 1000 User Manual
TDM services are carried by the primary link
The secondary link (equipment and air interface) is operating but not carrying user traffic
TDM ports on the secondary IDUs are tri-state
Switching to secondary will occur in the following cases:
Loss of the primary air interface due to sync loss
Loss of the primary air interface due to failure of the receiver to acquire expected
TDM data during a period of 24ms
Primary equipment power off (either ODU or IDU, local or remote)
The switching result would be:
TDM ports on the primary IDUs turn to tri-state
TDM ports on the secondary IDUs become active
TDM services are carried by the secondary link
Switching back to primary will occur as soon as the Primary link is fully functional for 1
second
Release 1.9.40
Chapter 12
12-14

Advertisement

Table of Contents
loading

Table of Contents