MIB Parameters
Table D-2: Private MIB Parameters (Sheet 9 of 18)
Name
winlink1000OduAirDualAntTxMode
winlink1000OduAirTxOperationMode
winlink1000OduAirDesiredNetMasterTxRatio
winlink1000OduAirCurrentNetMasterTxRatio
winlink1000OduAirMinUsableMasterTxRatio
winlink1000OduAirMaxUsableMasterTxRatio
winlink1000OduAirAccumulatedUAS
winlink1000OduAirAccumulatedUAS
winlink1000OduPerfMonCurrTable
winlink1000OduPerfMonCurrEntry
winlink1000OduPerfMonCurrUAS
winlink1000OduPerfMonCurrES
winlink1000OduPerfMonCurrSES
winlink1000OduPerfMonCurrBBE
winlink1000OduPerfMonCurrIntegrity
winlink1000OduPerfMonIntervalTable
winlink1000OduPerfMonIntervalEntry
winlink1000OduPerfMonIntervalIdx
winlink1000OduPerfMonIntervalUAS
winlink1000OduPerfMonIntervalES
winlink1000OduPerfMonIntervalSES
winlink1000OduPerfMonIntervalBBE
winlink1000OduPerfMonIntervalIntegrity
winlink1000OduPerfMonDayTable
winlink1000OduPerfMonDayEntry
winlink1000OduPerfMonDayIdx
WinLink 1000 User Manual
OID
1.3.6.1.4.1.4458.1000.1.5.58
1.3.6.1.4.1.4458.1000.1.5.59
1.3.6.1.4.1.4458.1000.1.5.60.1
1.3.6.1.4.1.4458.1000.1.5.60.2
1.3.6.1.4.1.4458.1000.1.5.60.3
1.3.6.1.4.1.4458.1000.1.5.60.4
1.3.6.1.4.1.4458.1000.1.5.61
1.3.6.1.4.1.4458.1000.1.5.62
1.3.6.1.4.1.4458.1000.1.6.1.1.1
1.3.6.1.4.1.4458.1000.1.6.1.1.2
1.3.6.1.4.1.4458.1000.1.6.1.1.3
1.3.6.1.4.1.4458.1000.1.6.1.1.4
1.3.6.1.4.1.4458.1000.1.6.1.1.5
Release 1.9.40
Type
Description
Integer
RW Description: Transmission type when using Dual
radios (MIMO or AdvancedDiversity using one
stream of data).
Integer
RW This parameter controls the Operation mode of
frames sent over the air.
either normal (1) for regular transmission where
frame size is determined by the traffic or
throughput test (2) when the user requests an
actual over the air throughput estimation using full
frames.
predetermined interval (default 30 sec).
Integer
RW This parameter is reserved to the element
manager provided with the product.
Integer
RO
Represents the actual Net Master Tx RAtio.
Integer
RO
Represents the minimal value the user can
configure for Desired net mAster Tx Ratio.
Integer
RO
Represents the maximal value the user can
configure for Desired net mAster Tx Ratio.
Integer
RO
Accumulates the Unavailable seconds of the Air
Interface.
Integer
RO
Possibilities of the link according to RFP and CBW
N/A This table defines/keeps the counters of the
current 15 min interval.
N/A This is an entry in the Current Interval Table.
INDEX {ifIndex }
Gauge
RO
The current number of Unavailable Seconds
starting from the present 15 minutes period.
Gauge
RO
Current number of Errored Seconds starting from
the present 15 minutes period.
Gauge
RO
Current number of Severely Errored Seconds
starting from the present 15 minutes period.
Gauge
RO
Current number of Background Block Errors
starting from the present 15 minutes period.
Integer
RO
Indicates the integrity of the entry.
N/A This table defines/keeps the counters of the last
day (in resolution of 15 min intervals).
N/A This is an entry in the Interval Table. INDEX
{ifIndex winlink1000OduPerfMonIntervalIdx }
RO
This table is indexed per interval number. Each
interval is of 15 minutes and the oldest is 96.
RO
The current number of Unavailable Seconds per
interval.
RO
Current number of Errored Seconds per interval.
RO
Current number of Severely Errored Seconds per
interval.
RO
Current number of Background Block Errors per
interval.
RO
Indicates the integrity of the entry per interval.
N/A This table defines/keeps the counters of the last
month (in resolution of days).
N/A This is an entry in the Days Table. INDEX {ifIndex
winlink1000OduPerfMonDayIdx }
RO
This table is indexed per interval number. Each
interval is of 24 hours and the oldest is 30.
Appendix D
The Operation mode is
The latter lasts no more than a
D-14

Advertisement

Table of Contents
loading