Grounding For Indoor/Outdoor Units; Odu Grounding; Figure 18-1 G - Radwin WinLink 1000 User Manual

Broadband wireless
Hide thumbs Also See for WinLink 1000:
Table of Contents

Advertisement

Grounding for Indoor/Outdoor Units

Figure 18-1: Grounding antenna cables
Grounding for Indoor/Outdoor Units

ODU Grounding

RADWIN Lightning Protection System uses a Shielded CAT-5e cable to interconnect the Out-
door (ODU) and Indoor (IDU) units.
However, this shielding does not provide a good lightning discharge path, since it can not tol-
erate the high Lightning Current surges.
To provide an alternate Lightning Discharge path, the ODU and antenna grounding posts
should be connected to ground point by a 10 AWG short copper wire.
The device should be permanently connected to ground.
WinLink 1000 User Manual
Release 1.9.40
Chapter 18
18-2