5.2.2 PROFINET Output Data

The following data is cyclically transferred from the host to the module. The data is arranged
in 16 bit words with the described meaning.
Cyclic output Data
Word 0: Parallel I/O
Output Bits
Bit 0:INTERNAL_CAL_IN (Rising Edge)
Bit 1:ZERO_IN (Rising Edge)
Bit 2:OFFSET_IN (Rising Edge)
Bit 3:TUNE_IN (Rising Edge)
Bit 4:EXTERNAL_CAL_IN (Rising Edge)
Bit 5:READ STANDARD LEAK_IN (High Level)
Bit 6:PARALLEL_ENABLE_IN (High Level)
Bit 7:AUTO_MANUAL_RANGE_IN (1= MANUAL) (High Level)
Bits 8-15:Reserved
Word 1: Command
Bits
Bit 0:ZERO ENABLE (1 = Enable)
Bit 1:PASSWORD ENABLE, (1 = Enable)
Bit 2:RANGESTOP ENABLE (1 = Enable)
Bit 3:AZ<0 (1 = ON, 0 = OFF)
Bit 4: Reserved
Bit 5:AUDIO MUTE (1= Muted , 0 = Audio ON)
Bit 6: Reserved
Bit 7: Reserved
Bit 8: Reserved
Bit 9: Reserved
Bit 10:SELECT EXTERNAL OR INTERNAL CAL (1 = External Calibration , 0 =
Internal Calibration)
Bit 11:ENABLE REJECT1(1 = Enable)
Bit 12:ENABLE REJECT2 (1 = Enable)
Bit 13:ENABLE REJECT3 (1 = Enable)
Bit 14:ENABLE REJECT4 (1 = Enable)
5-4
VS Series Component Leak Detector
Data words 0-2 can be modified at any time by the host. Changes
to these words will create the described action on the next cycle.
The bits in this word mirror the input bits on the parallel I/O
connector.