Connecting The Server Ups Unit To The Power Synchronized Unit - Fujitsu ETERNUS AF Series Configuration Manual

All-flash arrays, hybrid storage systems, disk storage systems, power synchronized unit
Hide thumbs Also See for ETERNUS AF Series:
Table of Contents

Advertisement

4.
Connection and Settings
Connecting to the Server UPS Unit
CAUTION

Connecting the Server UPS Unit to the Power Synchronized Unit

This section describes the procedure for connecting a power synchronized unit to a server UPS unit with the power
cord (for AC sensor).
Power cords (for AC sensor) must be obtained by customers.
Procedure
1
Connect the power cords (for AC sensor) to the power synchronized unit.
1-1
Connect the plugs of the power cords (for AC sensor) to SENSOR#0 port and SENSOR#1 port on the
power synchronized unit.
(for AC sensor)
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide (Power Synchronized Unit)
Do
When connecting external (signal, power, etc.) cables, avoid placing stress on
them. Not doing so may damage the cables.
Do Not
Do not forcibly bend or fold the cable. Doing so may damage the cable and cause
the power synchronized unit to malfunction.
90
Do not bend
more than 90 degrees
Power cord
SENSOR#0 port
Copyright 2019 FUJITSU LIMITED
Do not fold
SENSOR#1 port
54
P3AM-8012-14ENZ0