Analog Output Via Terminal 62/63 (Aout) - Lenze 9300 Series System Manual

Servo position controllers
Hide thumbs Also See for 9300 Series:
Table of Contents

Advertisement

Function library
Function blocks
3.5.8

Analog output via terminal 62/63 (AOUT)

3.5.8
Analog output via terminal 62/63 (AOUT)
Purpose
AOUT1 and AOUT2 can be used as monitor outputs.
Internal analog signals can be output as voltage signals and be used e.g. as display values or
setpoints for slaves.
Fig. 3−58
Analog output via terminal X6/62 (AOUT1)
Name
AOUT1−IN
AOUT1−GAIN
AOUT1−OFFSET
Fig. 3−59
Analog output via terminal X6/63 (AOUT2)
Name
AOUT2−IN
AOUT2−GAIN
AOUT2−OFFSET
Function
l
The value at input AOUTx−IN is multiplied by the value at input AOUTx−GAIN.
– The formula for the multiplication is: 100% * 100% = 100%.
l
The result of the multiplication is limited to ±200%.
l
The limited value is added to the value which is applied at input AOUTx−OFFSET.
– The formula for the addition is 50% + 10% = 60%. The result of the calculation is mapped
in such a way that 100% = 10 V.
l
The result of the addition is again limited to ±200%.
l
The result of the calculation is mapped in such a way that 100% = 10 V and is output as a
signal at terminal 62 or 63.
3−108
C0431
C0433
C0432
Signal
Type
DIS
DIS format
a
C0434/1
dec [%]
a
C0434/3
dec [%]
a
C0434/2
dec [%]
C0436
C0438
C0437
Signal
Type
DIS
DIS format
a
C0439/1
dec [%]
a
C0439/3
dec [%]
a
C0439/2
dec [%]
EDSVS9332P−EXT DE 2.0
AOUT1
C434/1
AOUT1-IN
+
62
+
AOUT1-GAIN
C0434/3
AOUT1-OFFSET
C0434/2
Source
CFG
List
Lenze
C0431
1
5001
C0433
1
19510
C0432
1
19512
AOUT2
C439/1
AOUT2-IN
+
63
+
AOUT2-GAIN
C0439/3
AOUT2-OFFSET
C0439/2
Source
CFG
List
Lenze
C0436
1
5002
C0438
1
19511
C0437
1
19513
Note
Note