11-Bit Character Frame (For 8-Bit Character) - Delta ASD-B2-0121-B User Manual

Asda-b2 series standard type ac servo drive for network communication application
Hide thumbs Also See for ASD-B2-0121-B:
Table of Contents

Advertisement

11-bit character frame (For 8-bit character)

8N2
Start
bit
8E1
Start
bit
8O1
Start
bit
Communication Protocol:
ASCII Mode:
STX
ADR
CMD
DATA(n-1)
.......
DATA(0)
LRC
End 1
End 0
RTU Mode:
STX
ADR
CMD
DATA(n-1)
.......
DATA(0)
CRC
End 1
Revision June 2010
0
1
2
8-data bits
11-bits character frame
0
1
2
8-data bits
11-bits character frame
0
1
2
8-data bits
11-bits character frame
Start character': ' (3AH)
Communication address: 1-byte consists of 2 ASCII codes
Command code: 1-byte consists of 2 ASCII codes
Contents of data: n word = n x 2-byte consists of n x 4 ASCII codes,
n≤12
Command code: 1-byte consists of 2 ASCII codes
End code 1: (0DH)(CR)
End code 0: (0AH)(LF)
A silent interval of more than 10ms
Communication address: 1-byte
Command code: 1-byte
Contents of data: n word = n x 2-byte, n≤12
Command code: 1-byte
A silent interval of more than 10ms
Chapter 8 MODBUS Communications
3
4
5
3
4
5
3
4
5
Stop
Stop
6
7
bit
bit
Even
Stop
6
7
parity
bit
Odd
Stop
6
7
parity
bit
8-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents