Special Function 2 - Delta ASD-B2-0121-B User Manual

Asda-b2 series standard type ac servo drive for network communication application
Hide thumbs Also See for ASD-B2-0121-B:
Table of Contents

Advertisement

Bit12
Bit12: Input power phase loss detection function
0: Enable Input power phase loss (AL022) detection function
1: Disable Input power phase loss (AL022) detection function
Bit13
Bit13: Encoder output error detection function
0: Enable encoder output error (AL018) detection function
1: Disable encoder output error (AL018) detection function
Bit15 Bit14
Bit14 ~ Bit15: Reserved. Must be set to 0.
P2 - 66
GBIT2
Default: 0
Applicable Control Mode: PT, S
Unit: N/A
Range: 0 ~ 0x000F
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Bit1 Bit0
Bit0 ~ Bit1: Reserved. Must be set to 0.
Bit2
Bit2: Undervoltage (Servo Drive Fault) clear mode selection
0: The fault, Undervoltage will not be cleared automatically.
1: The fault, Undervoltage will be cleared automatically.
Bit7 Bit6 Bit5 Bit4 Bit3
Bit3 ~ Bit7: Reserved. Must be set to 0.
Revision June 2010

Special Function 2

Chapter 7 Servo Parameters
Address: 0284H, 0285H
Related Section: N/A
7-67