Chapter 7 Servo Parameters
P1 - 76
AMSPD
Default: 5500
Applicable Control Mode: ALL
Unit: r/min
Range: 0 ~ 6000 (0: Disabled)
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to optimize the encoder outputs (OA, OB). When the users
set the actual reached maximum motor speed, the servo drive will equalize the
encoder outputs automatically. When P1-76 is set to 0, it indicates that equalizing
function is not available.
7-42
Max. Rotation Speed of Encoder Output
Address: 0198H, 0199H
Related Section: P1-46
Revision June 2010