P2 - 43
NCF2
Notch Filter 2 (Resonance Suppression)
Default: 1000
Applicable Control Mode: ALL
Unit: Hz
Range: 50 ~ 2000
Data Size: 16-bit
Display Format: DEC
Settings: 0: Disabled
This parameter is used to set second resonance frequency of mechanical system. It
can be used to suppress the resonance of mechanical system and reduce the
vibration of mechanical system. If P2-43 is set to 0, this parameter is disabled.
The parameters P2-23 and P2-24 are the first group of notch filter parameters and
the parameters P2-43 and P2-44 are the second group of notch filter parameters.
Notch Filter Attenuation Rate 2
P2 - 44
DPH2
(Resonance Suppression)
Default: 0
Applicable Control Mode: ALL
Unit: dB
Range: 0 ~ 32
Data Size: 16-bit
Display Format: DEC
Settings: 0: Disabled
This parameter is used to set magnitude of the resonance suppression that is set
by parameter P2-43. If P2-44 is set to 0, the parameters P2-43 and P2-44 are both
disabled.
P2 - 45
NCF3
Notch Filter 3 (Resonance Suppression)
Default: 1000
Applicable Control Mode: ALL
Unit: Hz
Range: 50 ~ 2000
Data Size: 16-bit
Display Format: DEC
Settings:
This parameter is used to set third resonance frequency of mechanical system. It
can be used to suppress the resonance of mechanical system and reduce the
Revision June 2010
Chapter 6 Control Modes of Operation
Communication Addr.:
0256H, 0257H
Related Section:
Section 6.3.7
Communication Addr.:
0258H, 0259H
Related Section:
Section 6.3.7
Communication Addr.:
025AH, 025BH
Related Section:
Section 6.3.7
6-25