Group 3: P3-xx Communication Parameters
P3 - 00
ADR
Default: 0x7F
Applicable Control Mode: ALL
Unit: N/A
Range: 0x01 ~ 0x7F
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
This parameter is used to set the communication slave address in hexadecimal
format. This address is an absolute address which represents the servo drive on a
RS-232/485 or CANbus network.
Display
Range
X: Axis number, the value must be within the range from 0 through F.
Y: Group number, the value must be within the range from 0 to through 7
If the AC servo drive is controlled by RS-232/485 communication, each drive (or
device) must be uniquely identified. One servo drive only can set one address. If
the address is duplicated, there will be a communication fault.
Please note:
1. This parameter does not provide broadcast function and does not respond
insecurity.
2. When the address of host (external) controller is set to 0xFF, it is with
auto-respond function. Then, the servo drive will receive from and respond to
host (external) controller both no matter the address is matching or not.
However, the parameter P3-00 cannot be set to 0xFF.
P3 - 01
BRT
Default: 0x0203
Applicable Control Mode: ALL
Unit: bps
Range: 0x0000 ~ 0x0055
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
This parameter is used to set the baud rate and data transmission speed of the
communications.
Revision June 2010

Communication Address Setting

0
0
-
-

Transmission Speed

Chapter 7 Servo Parameters
Related Section: Section 8.2
Y
X
0 ~ 7
0 ~ F
Related Section: Section 8.2
Address: 0300H, 0301H
Address: 0302H, 0303H