Molded-Case Circuit Breaker And Fuse Current Recommended Value - Delta ASD-B2-0121-B User Manual

Asda-b2 series standard type ac servo drive for network communication application
Hide thumbs Also See for ASD-B2-0121-B:
Table of Contents

Advertisement

2.5

Molded-case Circuit Breaker and Fuse Current Recommended Value

Caution: Please use molded-case circuit breaker and fuse which are recognized by and
comply with the UL or CSA standards.
Servo Drive Model
Operation Mode
ASD-B2-0121-B
ASD-B2-0221-B
ASD-B2-0421-B
ASD-B2-0721-B
ASD-B2-1021-B
ASD-B2-1521-B
ASD-B2-2023-B
ASD-B2-3023-B
Revision June 2010
Recommended Breaker
General
5A
5A
10A
10A
15A
20A
30A
30A
Chapter 2 Installation and Storage
Recommended Fuse (Class T)
General
5A
6A
10A
20A
25A
40A
50A
70A
2-5