Chapter 6 Control Modes of Operation
vibration of mechanical system. If P2-45 is set to 0, this parameter is disabled.

Notch Filter Attenuation Rate 3

P2 - 46
DPH3
(Resonance Suppression)
Default: 0
Applicable Control Mode: ALL
Unit: dB
Range: 0 ~ 32
Data Size: 16-bit
Display Format: DEC
Settings:
This parameter is used to set magnitude of the resonance suppression that is set
by parameter P2-45. If P2-46 is set to 0, the parameters P2-45 and P2-46 are both
disabled.

Low-pass Filter Time Constant

P2 - 25
NLP
(Resonance Suppression)
Default: 2 (1kW and below models) or
5 (above 1kW models)
Applicable Control Mode: ALL
Unit: 0.1ms
Range: 0 ~ 1000
Data Size: 16-bit
Display Format: DEC
Settings:
This parameter is used to set low-pass filter time constant of resonance
suppression. If P2-25 is set to 0, this parameter is disabled.
6-26
Communication Addr.:
025CH, 025DH
Related Section:
Section 6.3.7
Communication Addr.:
0232H, 0233H
Related Section:
Section 6.3.7