Relevant parameters:
P1 - 34
TACC

Acceleration Time

Default: 200
Applicable Control Mode: S
Unit: ms
Range: 1 ~ 20000
Data Size: 16-bit
Display Format: DEC
Settings:
This parameter is used to determine the acceleration time to accelerate from 0 to
its rated motor speed. The functions of parameters P1-34, P1-35 and P1-36 are
each individual. When P1-36 is set to 0 (Disabled), the settings of P1-34, P1-35 are
still effective. It indicates that the parameters P1-34 and P1-35 will not become
disabled even when P1-36 is disabled.
NOTE
1. When the source of speed command is analog command, the maximum setting
value of P1-36 is set to 0, the acceleration and deceleration function will be disabled.
2. When the source of speed command is analog command, the maximum setting
value of P1-34 is limited to 20000 automatically.
Revision June 2010
Chapter 6 Control Modes of Operation
Communication Addr.:
00144H, 0145H
Related Section:
Section 6.3.3
6-13