Chapter 7 Servo Parameters
Please note:
1. When servo is commanded off and the off delay time set by P1-43 has not
elapsed, if the motor speed is lower than the setting value of P1-38, the
electromagnetic brake will be engaged regardless of the off delay time set by
P1-43.
2. When servo is commanded off and the off delay time set by P1-43 has elapsed,
if the motor speed is higher than the setting value of P1-38, electromagnetic
brake will be engaged regardless of the current motor speed.
3. When the servo drive is disabled (Servo Off) due to a fault (except AL022) or by
EMGS (Emergency stop)) being activated, if the off delay time set by P1-43 is a
negative value, it will not affect the operation of the motor. A negative value of
the off delay time is equivalent to one with a zero value.
P1 - 44▲
GR1
Default: 16
Applicable Control Mode: PT
Unit: pulse
Range: 1 ~ (2
Data Size: 32-bit
Display Format: Decimal
Settings:
This parameter is used to set the numerator of the electronic gear ratio. The
denominator of the electronic gear ratio is set by P1-45. P2-60 ~ P2-62 are used to
set the additional numberators.
Please note:
1. In PT mode, the setting value of P1-44 can be changed only when the servo
drive is enabled (Servo On).
P1 - 45▲
GR2
Default: 10
Applicable Control Mode: PT
Unit: pulse
Range: 1 ~ (2
Data Size: 32-bit
7-34
Electronic Gear Ratio (1st Numerator) (N1)
-1)
26

Electronic Gear Ratio (Denominator) (M)

-1)
31
Address: 0158H, 0159H
Related Section:
Section 6.2.5
Address: 015AH, 015BH
Related Section:
Section 6.3.6
Revision June 2010