Connect To The Customer Management Network - Oracle FS1-2 Installation Manual

Flash storage system (not racked)
Hide thumbs Also See for FS1-2:
Table of Contents

Advertisement

are set exactly the same as the settings on the switches that connect the
system to the customer management network.
Note: Auto-negotiation is strongly recommended. If the customer's
Ethernet switch supports 1 GbE or 10 GbE, do not disable auto-negotiation.
Disabling auto-negotiation should be avoided.
6
Verify that you entered the correct settings for the IP address, netmask, and
gateway.
Note: Do not proceed to the next step until after you have verified the new
settings for the IP address, netmask, and gateway.
7
Click OK.
With the updated IP address, your laptop will lose connectivity to the
active Pilot.
8
To reconnect the laptop to the active Pilot, update the TCP/IP configuration
of the laptop to match the Pilot's newly configured IP address, netmask,
and gateway.
9
From the laptop, verify that you can log into the GUI using the updated IP
address.

Connect to the Customer Management Network

To enable the customer to manage the Oracle FS System, connect the Pilots to the
customer management network.
Prerequisites:
To ensure that Pilot 1 remains as the active Pilot, the laptop must be connected to
the NET 3 port on Pilot 1 until you are ready to connect the Pilots to the customer
management network. To avoid a fail over from Pilot 1, connect the Pilots to the
customer management network within five minutes of disconnecting the laptop
from Pilot 1.
If the laptop is disconnected from Pilot 1 and not connected to the customer
management network within five minutes, Pilot 1 will fail over to Pilot 2. Pilot 2
then becomes the active Pilot. Power cycle both of the Pilots to make Pilot 1
active again.
Configure and Connect to the Customer Management Network
The IP addresses of the Pilot management interface must be configured
before you connect the system to the customer management network.
Ensure that the IP address of the customer management network and the IP
addresses of the Pilots respond to a ping
The customer's firewalls allow the following TCP ports bi-directional access
between the management workstations and the IP addresses configured for
the Pilots:
TCP Port 80 for downloading the management software
TCP Port 26012 for access to the GUI and FSCLI
160