Iit Video Driver Failure - Xerox DocuColor 2240 Service Manual

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

3-319 IIT Video Driver Failure

Video Driver declared a DMA or compression error.
Procedure
Switch the power off then on. The problem continues.
Y
N
Return to Service Call Procedures.
Reinstall the software. If the problem continues, check the ESS PWB connectors (P/J Loca-
tions,
Figure
14). If the check is OK, replace the ESS PWB
Initial issue
DC 3535/2240/1632, WC M24
(PL
13.1).
09/03
2-21
3-320 IIT-ESS Communication Failure 1
Controller received check code error (incorrect parameter instruction).
Procedure
Switch the power off then on. The problem continues.
Y
N
Return to Service Call Procedures.
Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors (P/J Loca-
tions,
Figure
14). If the check is OK, replace the IIT/IPS PWB
(PL
18.3).
Status Indicator RAPs
3-319 , 3-320

Advertisement

Table of Contents
loading

This manual is also suitable for:

Docucolor 3535Docucolor 1632Workcentre m24

Table of Contents