3-358 IOT-ESS Communication Failure 18
Controller received check code error.
Procedure
Switch the power off then on. The problem continues.
Y
N
Return to Service Call Procedures.
Reinstall the software. If the problem continues, check the MCU PWB connectors (P/J Loca-
tions,
Figure
15). DC 3535 only: Replace the VSEL PWB
replace the MCU PWB
(PL
13.1).
Initial issue
DC 3535/2240/1632, WC M24
3-359 IOT-ESS Communication Failure 19
Controller received check code error.
Procedure
Switch the power off then on. The problem continues.
Y
Reinstall the software. If the problem continues, check the MCU PWB connectors (P/J Loca-
(PL
13.1). If the problem persists,
tions,
replace the MCU PWB
09/03
2-39
N
Return to Service Call Procedures.
Figure
15). DC 3535 only: Replace the VSEL PWB
(PL
13.1).
(PL
13.1). If the problem persists,