Checking Starter Motor - Kubota WSM 05-E4B Series Workshop Manual

Table of Contents

Advertisement

 SERVICING
4. Checking and adjusting
(A) Electrolyte specific gravity
(B) Discharge
(C) Good
NOTE
• Temperature
conversion
specific gravity.
• Battery electrolyte specific gravity changes
based on temperature.
• Insert the value identified on a specific
gravity meter into the following conversion
equation for temperature correction to learn
an accurate specific gravity value. (Standard
temperature assumed to be 20 ℃ [68 ℉].)
D
= D
+0.0007 (t -20)
20
t
D
= specific gravity value converted to
20
standard temperature of 20 ℃ (68 ℉)
D
= measured specific gravity value at the
t
electrolyte temperature t ℃

4.18 Checking starter motor

CAUTION
• To prevent an accidental short circuit, attach
the positive cable to the positive terminal before
the negative cable is attached to the negative
terminal.
• Do not remove the battery cap while the engine
operates.
• Keep electrolyte away from eyes, hands and
clothes.
If you are spattered with it, clean with water
immediately.
• Keep open sparks and flames away from the
battery at all times.
Hydrogen gas mixed with oxygen becomes very
explosive.
• Hold the starter to prevent its movement when
you do a test on the motor.
05-E4B SERIES,05-E4BG SERIES
(D) Charging is necessary.
of
electrolyte
IMPORTANT
• Do not disconnect or remove the battery when
you operate engine.
NOTE
• B terminal: It is the terminal that connects the
cable from the battery to the starter.
• C terminal: It is the terminal that connects the
cable from the motor to the magnet switch.
Tools required
• Circuit tester
• Jumper lead
1. Disconnect the negative cable from the battery.
2. Disconnect the positive cable from the battery.
3. Disconnect the leads from the starter B terminal.
4. Remove the starter from the engine.
5. Connect a jumper lead from the starter C terminal
(1) to the battery positive terminal (2).
6. Connect a jumper lead momentarily between the
starter body and the battery negative terminal (3).
(1) C terminal
(2) Positive terminal
(3) Negative terminal
[A] Electromagnetic drive type
NOTE
• If the motor does not operate, starter is
damaged, repair or replace the starter.
4. ENGINE
[B] Planetary gear reduction
type
4-27
KiSC issued 03, 2023 A

Advertisement

Table of Contents
loading

Table of Contents