Scrub Address Counter (Bits 7-4); Error Logger Register - Motorola MVME172 Programmer's Reference Manual

Vme embedded controller
Table of Contents

Advertisement

Scrub Address Counter (Bits 7-4)

This register reflects the current value in the Scrub Address Counter bits
7-4.
ADR/SIZ
BIT
31
NAME
SAC7
OPER
R/W
RESET
0 PLS

Error Logger Register

ADR/SIZ
BIT
31
NAME
ERRL
OG
OPER
R/C
RESET
0 PLS
SBE
MBE
ERA
http://www.mcg.mot.com/literature
1st $FFF43058/2nd $FFF43158 (8-bits)
30
29
28
SAC6
SAC5
SAC4
R/W
R/W
R/W
0 PLS
0 PLS
0 PLS
1st $FFF4305C/2nd $FFF4315C (8-bits)
30
29
28
ERD
ESCR
ERA
B
R
R
R
0 PLS
0 PLS
0 PLS
SINGLE BIT ERROR is set when the last error logged
was due to a single bit error. It is cleared when a 1 is
written to the ERRLOG bit. The syndrome code reflects
the bit in error. (Refer to the section on Syndrome
Decode.)
MULTIPLE BIT ERROR is set when the last error logged
was due to a multiple bit error. It is cleared when a 1 is
written to the ERRLOG bit. The syndrome code is
meaningless if MBE is set.
This bit provides status for a function that is not currently
used in the MCECC.
Programming Model
27
26
25
0
0
0
R
R
R
X
X
X
27
26
25
EALT
0
MBE
R
R
R
0 PLS
X
0 PLS
24
0
5
R
X
24
SBE
R
0 PLS
5-31