Functional Blocks; Local Bus To Vmebus Interface - Motorola MVME172 Programmer's Reference Manual

Vme embedded controller
Table of Contents

Advertisement

VMEchip2

Functional Blocks

2

Local Bus to VMEbus Interface

2-4
The following sections provide an overview of the functions provided by
the VMEchip2. See Figure 2-1 for a block diagram of the VMEchip2. A
detailed programming model for the local control and status registers
(LCSR) is provided in the following section. A detailed programming
model for the global control and status registers (GCSR) is provided in the
next section.
The local bus to VMEbus interface allows local bus masters access to
global resources on the VMEbus. This interface includes a local bus slave,
a write post buffer, and a VMEbus master.
Using programmable map decoders with programmable attribute bits, the
local bus to VMEbus interface can be configured to provide the following
VMEbus capabilities:
Addressing capabilities:
Data transfer capabilities:
The local bus slave includes six local bus map decoders for accessing the
VMEbus. The first four map decoders are general purpose programmable
decoders, while the other two are fixed and are dedicated for I/O decoding.
The first four map decoders compare local bus address lines A31 through
A16 with a 16-bit start address and a 16-bit end address. When an address
in the selected range is detected, a VMEbus select is generated to the
VMEbus master. Each map decoder also has eight attribute bits and an
enable bit. The attribute bits are for VMEbus AM codes, D16 enable, and
write post (WP) enable.
The fourth map decoder also includes a 16-bit alternate address register
and a 16-bit alternate address select register. This allows any or all of the
upper 16 address bits from the local bus to be replaced by bits from the
alternate address register. The feature allows the local bus master to access
any VMEbus address.
A16, A24, A32
D08, D16, D32