Motor Failure - Xerox Phaser 6360 Service Manual

Hide thumbs Also See for Phaser 6360:
Table of Contents

Advertisement

Motor Failure

Phaser 6300/6350/6360 Color Laser Printer Service Manual
Troubleshooting Procedure Table (Continued)
Step Actions and Questions
Test the Main Motor.
3
1. Close the Interlock Switch while
testing.
2. Run the Service Diagnostics Main
Motor test.
Does the motor operate?
4
Check for +24 V to the Main Motor.
Is there +24 V across P/J481-10 <=>
P/J 481-8?
5
Test the Interlock Switch.
Run the Service Diagnostics Interlock
Switch test.
Does the switch function correctly?
6
Check all pins on the FAN/PHD/MOT
Harness, PL10.1.9 for continuity.
1. Disconnect P/J48 and P/J481.
2. Check continuity between J48 <=>
J481.
One of the primary drive motors has failed.
Applicable Status Code:
Code 106:
Motor Failure
Troubleshooting Reference Table
Applicable Parts
Main Drive Assembly, PL8.1.2
Developer Drive Assembly,
PL8.1.1
Fuser Drive Assembly, PL5.2.25
Engine Control Board, PL9.1.16
Interlock Switch, PL9.1.11
Troubleshooting Procedure Table
Step Actions and Questions
1
Check the motors.
Run the Service Diagnostics motor
tests to determine the failed part.
Is the failed part the Main Drive
Motor?
Error Messages and Codes
Yes
Go to Step 5.
Go to Step 6.
Go to Step 6.
Replace the
Engine Control
Board
(page 8-106).
Wiring and Plug/Jack References
Print Engine Map 2 - P/J Locator (page 10-6)
Print Engine Drive Wiring (page 10-19)
Print Engine Wiring Fuser (page 10-22)
Yes
Go to
(page 3-84).
No
Go to Step 4.
Go to Step 5.
Replace the
Interlock Switch
(page 8-102).
Replace the
FAN/PHD/MOT
Harness.
No
Test the Fuser
Motor.
3-85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phaser 6300Phaser 6350

Table of Contents