General Troubleshooting
Control Panel Troubleshooting
No Control Panel Display after Power Is Turned On
Control Panel LED Is On, Control Panel Display Is Blank
4-12
1.
Remove and reseat the Image Processor Board (page 8-99).
2.
Print an Engine Test Print (page 5-10).
3.
Replace the Image Processor Board (page 8-99) (if Step 2 passes).
4.
See "DC Power Supply Troubleshooting" on (page 4-15).
5.
Replace the Control Panel (page 8-13).
6.
Replace the Control Panel wiring harness (page 8-13).
1.
Remove and reseat the Image Processor Board (page 8-99).
2.
Replace the Control Panel (page 8-13).
3.
Replace the Control Panel wiring harness.
4.
Replace the Image Processor Board (page 8-99).
Phaser 6300/6350/6360 Service Manual