Error Messages and Codes
Motor Errors
Fan Motor Error
3-66
The Fan Motor is not in operation.
Applicable Chain Link
042-313: Fan Motor Error
Initial Actions
Cycle printer power.
If the problem persists, follow the procedure below.
Troubleshooting Reference Table
Applicable Parts
MCU Board, PL8.2.13
LVPS Harness Assy, PL9.1.3
FAN, PL8.1.1
LVPS Board, PL8.2.1
Troubleshooting Procedure Table
Step
Actions and Questions
1
Perform the Fan test (page 4-31):
Service Mode
HIGH.
Does the Fan operate properly?
2
Check the connection between the FAN
and LVPS.
Is P/J503 on the LVPS connected
correctly?
Does the error still occur when the
3
power is turned OFF and ON?
4
Check the connections between the
LVPS and MCU Board.
Are P/J501 and P/J14 connected
correctly?
Does the error still occur when the
5
power is turned OFF and ON?
Wiring and Plug/Jack Map References
"Map 1 - Transfer Unit, Control Panel,
Imaging Unit, Dispenser, Fuser" on
page 10-8
"Map 4 - Toner Dispenser Motors, HVPS,
MCU" on page 10-11
"DC Power Supply" on page 10-17
Yes
Replace the
>
Engine Diag
>
Fan
MCU Board.
(page 8-59)
Go to step 4.
Go to step 4.
Go to step 6.
Go to step 7.
Phaser 6125/6130 Color Laser Printer Service Manual
No
Go to step 2.
Reconnect the
connector P/
J503 correctly,
then go to step
3.
Complete
Reconnect the
connector(s) P/
J501 and P/J14
correctly, then
go to step 5.
Complete