Ac Power Supply Troubleshooting; Dc Power Supply Troubleshooting - Xerox Phaser 6360 Service Manual

Hide thumbs Also See for Phaser 6360:
Table of Contents

Advertisement

AC Power Supply Troubleshooting

DC Power Supply Troubleshooting

Phaser 6300/6350/6360 Service Manual
+24 VDC Output Stopped By Interlock Switch
Opening Door A or B opens the Interlock Switch. This shuts off the +24 VDC
supplied to the motors, clutches, and solenoids.
Troubleshooting Reference Table
Applicable Parts
LVPS, PL9.1.6
Troubleshooting Procedure Table
Step Action and Questions
Check the voltage at the AC wall outlet.
1
Is there approximately 110 VAC (or 220 VAC
if the printer is a 220 V configuration) at the
AC wall outlet?
Check the power cord for defects or a loose
2
connection.
Note
If an internal short has occurred, the LVPS requires several minutes to
reset.
Troubleshooting Reference Table
Applicable Parts
LVPS, PL9.1.6
Troubleshooting Procedure Table
Step Action and Questions
Perform the AC power supply
1
troubleshooting procedure.
Does the problem persist?
Turn the AC power Switch Off.
2
Is the fuse (F101) on the low-voltage
power supply board open?
Wiring and Plug/Jack References
Print Engine Power Wiring Diagram (page 10-17)
Yes
Go to Step 2.
Replace or
reseat the
power cord.
Wiring and Plug/Jack References
Print Engine LVPS and Drive P/J Locator (page 10-6)
Print Engine Power Wiring Diagram (page 10-17).
Yes
Go to Step 2.
Replace the LVPS
(page 8-100).
General Troubleshooting
No
Notify the
customer of
improper AC
output from
the outlet.
Replace the
LVPS
(page 8-100).
No
Complete
Go to Step 3.
4-15