Xerox Phaser 6360 Service Manual page 204

Hide thumbs Also See for Phaser 6360:
Table of Contents

Advertisement

General Troubleshooting
4-16
Troubleshooting Procedure Table (Continued)
Step Action and Questions
1. Disconnect the connectors J163,
3
J164 and J165 from the LVPS.
2. Turn the AC power switch On.
3. Verify the DC voltages between the
following pins on the LVPS:
P163-1 <=> P163-2 = +24
VDC?
P164-1 <=> P164-4 = +3.3
VDC?
P165-2 <=> P165-3 = +5
VDC?
P165-4 <=> P165-5 = +3.3
VDC?
4
1. Turn the AC power switch Off.
2. Connect J164 to the LVPS then turn
the AC power switch On.
P/J164-1 <=>P/J164-4 = +3.3
VDC?
5
Check the following parts for fault or
damage:
LVRPG Harness, PL10.1.3.
Engine Control Board, PL9.1.16
Does the problem recur?
6
7
1. Turn the AC power switch Off.
2. Connect J165 to the LVPS then turn
the AC power switch On.
3. Verify the DC voltages between the
following pins on the LVPS:
P/J165-2 <=> P/J165-3 = +5
VDC?
P/J165-3 <=> P/J165-4 =
+3.3 VDC?
Check the LV Harness, PL10.1.2 for
8
fault or damage.
Does the error recur?
9
Turn the AC power Switch OFF
10
Connect J163 to the LVPS then turn
the AC power switch ON.
P/J163-1 <->P/J163-2 = +24 VDC?
Check the 24V Harness, PL10.1.1 for
11
fault or damage.
Yes
No
Go to Step 4.
Replace the
LVPS
(page 8-100).
Go to Step 7.
Go to Step 5.
Replace if
Go to Step 7.
damaged or
defective.
Go to Step 7
Complete
Go to Step 10.
Go to Step 8.
Replace if
Go to Step 10.
damaged or
defective.
Go to Step 10.
Complete
Complete
Go to Step 11.
Replace if
Complete
damaged or
defective.
Phaser 6300/6350/6360 Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phaser 6300Phaser 6350

Table of Contents