Advanced: Lamp Menu

The Lamp menu provides controls for optimizing lamp alignment (LampLOC™), maintaining a specific light
output over time (LiteLOC™), or setting a precise power level for the lamp. Two read-only areas display
related lamp performance details-the bar graph represents the current light output and, if LiteLOC™ is
enabled, a heavy line shows the chosen LiteLOC™ setting. In addition, the New Lamp button activates a
window for entering the serial number of a newly installed lamp. This button is also available with an Operator
login with the rest of the Lamp menu disabled-refer to Figure 3-4.
Set/maintain consis-
tent light output.
Adjustable from 75%
- 110% if LiteLOC™
is not in use (or as
temporary override).
Position lamp for best
light output.
x axis = horizontal
y axis = vertical
z axis = fore/aft
Table 3.10 Advanced: Lamp Menu Options
ADVANCED: LAMP MENU OPTIONS
LiteLOC
Set (Brightness)
Lamp Power
LampLOC
Lamp (read-only)
New Lamp
Light Level
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)
Figure 3-17 Advanced: Lamp Menu Options
Maintains a chosen light level at the screen over time-the lamp ballast will gradually increase power to
the lamp as necessary, until it reaches the maximum level possible for the installed lamp. To disable
LiteLOC™ temporarily or permanently, clear the LiteLOC
directly.
With the desired light output measured at the screen (typically 14 Fl), press the Set button to automati-
cally enable LiteLOC
. The current brightness level will be maintained as long as possible. NOTE:
Arbitrary units-of-measure appear here, not footlamberts or lumens.
Indicates what percentage of power (appropriate for the installed lamp) to supply to the lamp, automat-
ically overriding any LiteLOC
The LiteLOC
line and Set values will not change unless Set is clicked (defining a new LiteLOC
setting). Refer to Table 8.1 Minimum and Maximum Lamp Power by Lamp Type, on page 8-6 for
lamp power ranges.
LampLOC
buttons activate motors that reposition the bulb in the projector for optimized light out-
put. Use the Do Auto button (recommended) or the individual buttons. NOTES: 1) Lamp must be ON
to begin. If it is turned OFF during a re-positioning, the bulb will return to its former position. 2)
Douser opens and remains non-functional during a LampLOC
Indicates the current lamp age, amps (current), volts (voltage) and watts (lamp power). Read-only.
Activates the lamp history window and text editing box for recording a new lamp's serial number,
which resets the lamp timer.
Indicates current light output (shown as solid vertical bar) and LiteLOC
line). Consider the value at the top of the meter as arbitrary-i.e., not representing actual lumens or fL.
Read-only lamp info.
setting that may be in effect. This causes the bar graph to rise or fall.
Section 1: Introduction
Current light sensor
reading.
LiteLOC™ setting
(desired brightness).
Light Output (sensor
reading).
Click to record new
lamp serial # and
reset lamp timer.
Enable checkbox or adjust Lamp Power
adjustment.
level set (single horizontal