Christie CP2000-SB User Manual page 176

Hide thumbs Also See for CP2000-SB:
Table of Contents

Advertisement

Function Code / Examples
Data Format (DTF)
(DTF)
Data Logging (DLG)
(DLG 1)
(DLG?)
(DLG!002)
Error Message Enable (EME)
(EME 1)
(EME!001)
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)
Description and Parameters
Selects the source type and packing mode for the current input.
Cinema source A or B:
0x00 = 4:2:2 unpacked, 10-bits/color (default)
0x01 = 4:2:2 packed, 12-bits/color
0x02 = 4:4:4 unpacked, 10-bits/color
0x03 = 4:4:4 packed, 12-bits/color
Cinema dual link (A and B):
0x00 = 4:2:2 packed, 10-bits/color with O/E pixels (default)
0x01= 4:2:2 packed, 10-bits/color with O/E lines
0x02 = 4:2:2 packed, 12-bits/color with O/E lines
0x03 = 4:2:2 packed, 12-bits/color with O/E pixels
0x04 = 4:4:4 unpacked, 10-bits
0x05 = 4:4:4 packed, 10-bits/color, mixed
0x06 = 4:4:4 packed, 10-bits/color, O/E pixels
0x07 = 4:4:4 packed, 12-bits
DVI port:
0x00 = Unpacked, 8-bits/color (default)
0x01 = Packed, 10-bits/color
0x02 = Packed, 12-bits/color
0 = Minimum logging of activities—i.e., for errors only
1 = Standard logging (errors plus select operations)
2 = All activities are logged
Enable error messages sent via Ethernet, where
0= disabled and 1= enabled. Refer to ERR.