3.5.1 TPC Main Menu

8 Display Buttons (channels)
1. Select pre-defined source.
2. Image will change.
3. Additional sources on 2nd
page.
Channel Menus
Status Button
• Go to Status Menu.
• Flash indicates an alarm
condition.
• Color indicators described
below.
Status
NOTE: The
TURN THE LAMP ON or OFF: To toggle the lamp ON/OFF, press and hold the lamp button.
LOG ON: By default, with no login, the TPC will offer only the three general user menus intended for daily
operation. If you need to access additional functions offered in other menus, you must log on as a specific user
with more rights. Press the user level icon in the bottom right corner of any screen then enter the desired user
name and password in the text boxes provided.
OPEN OR CLOSE THE DOUSER (SHUTTER): To blank the display for instant picture muting and cooler
stand-by mode, press the raised douser (shutter) key showing a lens that is currently projecting light. Closing
the douser slides a shutter blade in front of the lens and reduces lamp power to 50% of its maximum rating. To
open the douser and restore previous lamp power, press the depressed douser key showing a darkened lens
with red warning circle.
MOVE THE AUXILIARY LENS: Toggle the current location of the optional auxiliary lens: position it
either in front of the primary lens to stretch the display horizontally, or move it aside. NOTE: For complete
operating instructions, refer to the information supplied with the Motorized Auxiliary Lens Mount.
SEE TEST PATTERNS: To display a test pattern, press the Test Pattern button-repeat to cycle through
available test patterns. To return to a presentation, toggle the Test Pattern button again or select one of the 8
display buttons from a Main menu page. NOTES: 1) Allow 2-3 seconds for each test pattern to appear. 2) The
number and type of available test patterns depends on what the installer loaded during installation. 3) Any
user beyond the General User can also choose from the complete range of test patterns offered in the
password-protected Advanced menu.
START FEATURES or PRESENTATIONS: To start a different feature or presentation, press its correspond-
ing display button.
STATUS BUTTON: Color indicators,
Green = All OK
Yellow = Environment/Diagnostics WARNING
Red = Environment/Diagnostics CRITICAL ERROR
Flashing = ALARM CONDITION
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)
Figure 3-5 Main Menu Options
User
and
buttons in the bottom corners do not affect the projected display image.
Section 1: Introduction
Lamp ON/OFF.
Douser Button - Open
and close the shutter.
Anamorphic Lens - In/
Out.
Test Patterns - Cycle
through available test
patterns.
Lens - Intelligent Lens
System. Select to adjust
lens mount.
User Level Button -
Color identifies user
rights. Select to
change.