Section 1: Introduction
Admin: Lamp Menu
Record light
measured for
both extremes
of power.
• Measured at
screen
• Projector will
be able to inter-
polate future
light output in
foot lamberts
Select to
implement new
values.
Table 3.20 Summary of Admin: Lamp Menu Options
ADMIN: LAMP MENU OPTIONS
Footlamberts
Calibration

Admin: GPIO Menu

Use the Admin: GPIO menu to configure GPI macros for LAMP ON/OFF, DOUSER OPEN/CLOSE and
AUXILIARY LENS IN/OUT and also GPO macros for LAMP STATE, DOUSER STATE, AUXILIARY
LENS STATE and SYSTEM HEALTH STATUS. NOTES: 1) Only GPIO 1-5 can be programmed. 2) Use of
GPIO for 3D will automatically un-program any other use for that pin.
GPI macro name.
Predefined macro.
GPO Macro name.
Predefined macro.
3-48
Figure 3-36 Admin: Lamp Menu Options
Activate each text box to automatically drive the lamp at its minimum or maximum power. record light
measured at the screen for both extremes in power, defining a range of footlamberts possible. Light readings
(fL) appearing elsewhere in TPC will then be interpolations based on this range. Click SAVE to implement
new values. NOTE: Re-calibration must be done with new lamp change.
Figure 3-37 Admin: GPIO Menu Options
Select to
automatically
reduce lamp
power to its
minimum.
Select to
automatically
increase lamp
power to its
maximum.
CP2000-SB User Manual