Regulatory - Christie CP2000-SB User Manual

Hide thumbs Also See for CP2000-SB:
Table of Contents

Advertisement

Section 1: Introduction
Table 8.1 Minimum and Maximum Lamp Power by Lamp Type
Lamp Type
Other-16
Other-20
CXL-20
CDXL-20
Other-30
CXL-30
CDXL-30
CDXL-30SD
Other-45
CXL-45
CDXL-45
Other-60
CXL-60
CDXL-60
CDXL-60SD
Type
Stand-by lamp power level for 4-6 kW
Stand-by lamp power level for 2-3 kW
Motorized adjustment of position
Recommended screen widths:
2.0 kW =45 ft. nominal
3.0 kW =55 ft. nominal
4.5 kW =65 ft. nominal
6.0 kW =75 ft. nominal
8.7

Regulatory

Audible Noise
Safety
EMC Emissions
EMC Immunity
8-6
Min Lamp Power
Max Lamp Power
1200W (75%)
1760W (110%)
1500W (75%)
2200W (110%)
1500W (75%)
2200W (110%)
1000W (50%)
2200W (110%)
2000W (67%)
3300W (110%)
1000W (33%)
3300W (110%)
2000W (67%)
3300W (110%)
2000W (67%)
3300W (110%)
3375W (75%)
4950W (110%)
1500W (33%)
4950W (110%)
2300W (51%)
4950W (110%)
4500W (75%)
6600W (110%)
2000W (33%)
6600W (110%)
2750W (46%)
6600W (110%)
2750W (46%)
6600W (110%)
70 dBA maximum. NOTE: Does not include customer-supplied external extractor fan.
• UL 60950-1 and CAN/CSA C22.2. No. 60950-1-03 1st edition, bi-national.
• IEC 60950-1:2001
• FCC CFR47, Part 15, Subpart B, Class A - Unintentional Radiation
• CISPR 22: 2003 +A1:2004 / EN55022: 1998 +A2:2003, Class A - Information Technology Equipment
CISPR 24:1997 / EN55024:1998 +A1:2001 +A2:2003 EMC Requirements - Information Technology
Equipment
Xenolite®
50% of lamp's maximum current rating
75% of lamp's maximum current rating
3-axis, 0.25" range for each
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents