Christie CP2000-SB User Manual page 193

Hide thumbs Also See for CP2000-SB:
Table of Contents

Advertisement

Section 1: Introduction
P1
If P1 = 1
System Status
If P1 = 2
Signal Information
If P1 = 3
Operation Status
B-20
P2
0 = Power Status (0=Off, 1=On)
2 = LiteLOC™ (0=Off, 1=On)
3 = Lamp Expiry
4 = Lamp Hours
5 = Total Lamp Hours
7 = Projector Hours
8 = Shutter (0=Off, 1=On)
20 = Lamp Current
21 = Lamp Voltage
22 = Lamp Power
23 = Approximate foot lamberts
0 = Signal Status (0=OK, 2=invalid)
1 = Channel #
2 = Vertical Frequency
3 = Test Pattern (0=Off, >0=On)
2 = Lamp Error
10 = Card cage temperature
11 = Blue DMD temperature
12 = Red DMD temperature
13 = Integrator temperature
14 = Prism temperature
15 = SSM temperature
16 = ILS temperature
20 = Lamp vane switch interlock
21 = Extractor vane switch interlock
22 = Lamp door interlock
23 = Auxiliary interlock / High current
24 = Tamper switch
30 = Intake fan #1 (rear) speed
31 = Intake fan #2 (front) speed
32 = Card cage fan speed
33 = LAD fan speed
40 = SmpteATotalErr
41 = SmpteARecentErr
42 = SmpteBTotalErr
43 = SmpteBRecentErr
50 = SecurityInstalled
51 = SecurityArmed
52 = SecurityTamper
53 = CompLidOpen
54 = NonCompLidOpen
55 = CommFailure
56 = BatteryLow
Notes
Good or bad signal
Current channel (101-132)
Current vertical frequency
0=OK, 1=Unexpected lamp
OFF, 2=Lamp failed to ignite
°C. Shows caution or critical
°C. Shows caution or critical
°C. Shows caution or critical
°C. Shows caution or critical
°C. Shows caution or critical
°C. Shows caution or critical
°C. Shows caution or critical
(0 = OK, 1 = open)
(0 = OK, 1 = open)
(0 = OK, 1 = open)
(0 = OK, 1 = open)
(0 = OK, 1 = open)
RPM. Also indicates "slow" or
"failed" condition.
"
"