Section 1: Introduction
ENVIRONMENT
Projector Hours
Total Lamp Hours
Lamp
Current
Voltage
Power
Footlamberts
™
LiteLOC
Interlocks
†
Lamp Fan
(rear of projector)
†
Extractor Fan
†
Lamp Door
(louvered lamp door)
Auxiliary
†
Tamper
(projector lid)
Temperatures (°C or °F) *
Card Cage
DMD – Blue
DMD – Red
Integrator
Prism
SSM
Fan *
Fan #1 ("Intake #1")
Fan #2 ("Intake #2")
Card cage
LAD
SECURITY ENCLOSURE NOTE: If any of the following indicators are "red", service is needed.
Security Enclosure Installed
Security Enclosure Armed
Security Tamper
Component Side Lid Open
Non-Component Side Lid Open
Enclosure Communication Failure
Security Enclosure Battery Low
3-14
(for ducting to outside world)
# hours projector has been powered up and communicating with the TPC
# hours logged for all lamps ever installed
# hours logged on current lamp
Lamp current (# amps)
Lamp voltage (# volts)
Lamp power (# watts)
Footlamberts (interpolated from min/max calibration)
On/Off/At Maximum Power
Critical safety and/or operation monitoring
OK/Failure. Failure also triggers an alarm window
OK/Failure. Failure also triggers an alarm window
OK/Failure. Failure also triggers an alarm window
OK/Failure. Failure also triggers an alarm window
OK/Failure. Failure triggers an alarm window and stops CineLink
encrypted cinema processing.
Critical internal temperatures in °C or °F
55-69°C=warning
>70°C=critical
60-64°C=warning >65°C=critical
60-64°C=warning
>65°C=critical
95-104°C=warning >105°C=critical
>75°C=critical
70-74°C=warning
>60°C=critical
55-59°C=warning
Speed (RPMs) of 4 internal cooling fans
st
RPMs of 1
primary fan (exhaust side of proj.)
nd
RPMs of 2
primary fan (exhaust side of proj.)
RPMs of electronics card cage fan
RPMs of laminar airflow device for DMDs
®
2 -
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)