Advanced: Lens Menu - Christie CP2000-SB User Manual

Hide thumbs Also See for CP2000-SB:
Table of Contents

Advertisement

Advanced: Lens Menu

As shown in Figure 3-20, use the fields provided in the Lens menu to select a lens type and record its serial
number.
Select lens type
from drop-down
list.
Intelligent
Lens System:
Calibrate ILS.
Table 3.12 Advanced: Lens Options
ADVANCED: LENS OPTIONS
Primary Lens
Auxiliary Lens
Serial Number
Installed
Lens Reset On Startup
Calibrate
Lens Reset
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)
Figure 3-20 Advanced: Lens Menu Options
From the drop-down menu, select the type of primary lens installed on the projector.
If an auxiliary lens is installed, select it from this drop-down list. The selections include
anamorphic and wide converter lens. This selection is grayed-out when there is no auxiliary
lens connected.
Enter serial number of the installed lens.
Enables/disables the Intelligent Lens System (ILS). NOTE: Installed must be checked in
order to use ILS functionality.
Select this checkbox for the ILS to locate the sensor flags and the backlash of each motor at
the same time. Keep checked if you need to reset the lens often.
Click Calibrate to calculate the amount of backlash for each motor and make the necessary
adjustments to ensure proper motor range. Calibration should only be used when changing
lenses and is a necessary step at that time.
When Lens Reset is clicked, the motors on the lens move to a central location (mechanical
center) before moving back to the original position. This feature is useful for initiating an auto
lens reset. Each motor can either be reset individually or select All Axes when prompted to
reset the 4 motors in succession.
Section 1: Introduction
Enter serial
number for the
newly installed
lens.
3-31

Hide quick links:

Advertisement

Table of Contents
loading