IF INTERNAL
Sources/servers are often rack-mounted in the projector rear with cabling routed directly to the underside of
the projection head. See Figure 2-25 and Figure 2-26. Install as follows:
1. Remove the pair of rack protector posts from the rear of the pedestal.
2. Remove the required horizontal rack covers (security plates).
3. Rack-mount the desired equipment within the pedestal.
4. Re-install the pair of rack protector posts. Keep extra covers.
Do not modify any CP wiring or lead dress during installation and ensure the added device does not interfere
with normal CP operation.
Power normally is hard-wired to the TB2 terminal block. NOTE: Internal power connection is not possible if
incoming AC feed is 4-wire 3-phase only, as the TB2 terminal has no power in this case.
NOTE: The DVI ports are single-link ports for single-link cable/connectors only. Using as a dual-link pair
requires a special adapter (not currently available).
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)
Figure 2-25 Connecting an Internal Cinema Server/Source
Figure 2-26 Connecting an Internal Non-cinema (DVI) Source