Special Adjustments for Some AC Supplies
AC levels can vary depending on region. Check the following when installing.
NOTES: 1) Requires voltmeter for up to 400 VAC. 2) Consult the Interconnect Drawing in pedestal. 3)
Disconnect from AC power before moving the jumpers.
JUMPER FROM IGNITER TERMINAL 2:
As set from the factory, the igniter jumper
located on terminal 2 connects to T2. This
configuration is used when 207-265 VAC
are present (as it is for most countries). If
you find your incoming AC is below 207
VAC, connect terminal 2 jumper to T1
instead.
• If AC between terminals 2 and 3 is
207-265, connect terminal 2 to T2
(factory default).
• If AC between terminals 2 and 3 is
180-207, connect terminal 2 to T1.
See Figure 2-21.
BALLAST 115 VAC TAPS:
Ensure your nominal line between the
terminals labeled 115V and COMMON
(or 0V) is within 10% of 115 VAC. See
Figure 2-22.
• If your measurement at the 115V ter-
minal is 126.5V or more, move the 115V wires to the tap labeled –10%.
• If your measurement at the 115V terminal is 103.5V or less, move the 115V wires to the tap labeled
+10%.