a. To create this loop, connect the OUT/warm and IN/cool hoses as described below. NOTE: Hose con-
nections may not be labeled. Be sure to depress each hose connector tab before inserting the hose end,
then release to seal (Figure 2-15). This prevents damage caused by forcing the gasket end into a closed
connector. Listen for a click.
b. The long loose hose connected to the reservoir is the OUT/warm hose from the projection head. Con-
nect to the projection head location closest to the non-operator's side of the projector.
c. The short loose hose connected to the heat exchanger is the IN/cool hose. Connect to the projector
head location closest to the operator's side of the projector.
Important! To prevent damage to the sealing gasket, always depress the connector tab when inserting the
hose end. Avoid forcing together and listen for click.
STEP 7 - Fill the Reservoir Completely (Initial Filling for Hosts Only)
NOTE: Disconnect the projector from AC power before filling the reser-
voir.
After connecting the hoses, completely fill the cooler reservoir with Chris-
tie approved coolant Jeffcool E105 provided in the liquid coolant fill ser-
vice kit (P/N 003-001837-02). Danger! HAZARDOUS SUBSTANCE - The
coolant used in this product contains ethylene glycol. Use caution when
handling. Do not ingest. For this first filling, fill the reservoir completely.
Virtually all of this first supply of liquid will be drained into the hoses upon
initial power-up, at which point the reservoir must be re-filled to the correct
level at the gauge window. Refer to
STEP 8 - Check Lead Dressing & Hoses
a. At this point, integral pedestal-to-head cabling and hose connection
should be complete. Check all lead dressing and secure as neatly as possible to prevent extra cable
lengths from dangling or touching other components. Provide proper strain relief as necessary. Ensure
hoses are free of kinks and sharp turns.
b. Connect sources and communication links at any time. Refer to
Sources
2-10
Figure 2-15 Connecting the Hoses
Section 2.5 Initial Power
and
Section 2.3 Connecting for Communications.
Up.