Srx 210 Services Gateway Environmental Specifications - Juniper SRX 210 Services Hardware Manual

Services gateway
Hide thumbs Also See for SRX 210 Services:
Table of Contents

Advertisement

Appendix B
SRX 210 Services Gateway Environmental
Specifications

SRX 210 Services Gateway Environmental Specifications

This section includes the following topic:
SRX 210 Services Gateway Environmental Specifications on page 155
Table 37 on page 155 provides the required environmental conditions for normal SRX
210 services gateway operations. In addition, the site must be as dust-free as possible
because dust can clog air intake vents and filters, reducing the efficiency of the
cooling system.
Table 37: SRX 210 Services Gateway Environmental Specifications
Description
Altitude
Temperature
Maximum thermal output
NOTE: Install the device only in restricted areas, such as dedicated equipment rooms
and equipment closets, in accordance with Articles 110–16, 110–17, and 110–18
of the National Electrical Code, ANSI/NFPA 70.
Value
No performance degradation to 10,000 ft (3048 m)
Normal operation ensured in temperature range of 32°F (0°C) to
104°F (+40°C)
Nonoperating storage temperature in shipping container: –40°F
(–40°C) to 158°F (70°C)
The maximum thermal values for the three types of services
gateways are as follows:
Low Memory — AC power: 120 BTU/hour (35 W)
High Memory — AC power: 126 BTU/hour (37 W)
PoE — AC power: 327 BTU/hour (96 W)
NOTE: These specifications are estimates and subject to change.
SRX 210 Services Gateway Environmental Specifications
155