Table 35: SRX 210 Services Gateway Chassis Alarm Conditions and Corrective Actions (continued)
Component
Alarm Conditions
Hardware
An error occurred during
components
the process of reading or
on services
writing to the NAND
gateway
flash.
The services gateway
chassis temperature is
too warm
The services gateway fan
has failed.
NOTE: For more information on the alarms, see the JUNOS Software Administration
Guide.
Related Topics
Monitoring the SRX 210 Services Gateway Power System
The LEDs on the services gateway enable you to determine the performance and
operation. The Power LED, located on the front panel of the services gateway indicates
the different settings with respect to the power system.
Table 36 on page 126 describes different Power LED status settings and their corrective
actions:
Action
Reformat the NAND flash and install a bootable image. (See the
JUNOS Software Administration Guide.)
If this remedy fails, contact JTAC. See "Juniper Networks Technical
Assistance Center" on page 128.
Check the room temperature. See "SRX 210 Services Gateway
Environmental Specifications" on page 155.
Check the air flow. See "General Site Guidelines for Installing
the SRX 210 Services Gateway" on page 43.
Check the fans. See "SRX 210 Services Gateway Cooling
System" on page 21
If you must replace a fan, contact JTAC. See "Juniper Networks
Technical Assistance Center" on page 128.
Place your hand near the exhaust vents at the rear of the chassis
to determine whether the fan is pushing air out of the chassis.
Replace the failed fan. Contact JTAC. See "Juniper Networks
Technical Assistance Center" on page 128.
CLI on the SRX 210 Services Gateway on page 121
Monitoring the SRX 210 Services Gateway Components using LEDs on page 122
Monitoring the SRX 210 Services Gateway Power System on page 125
Using the Reset Config Button on the SRX 210 Services Gateway on page 127
Changing the Reset Config Button Behavior on the SRX 210 Services
Gateway on page 127
Juniper Networks Technical Assistance Center on page 128
Monitoring the SRX 210 Services Gateway Power System
Chapter 14: Troubleshooting the SRX 210 Services Gateway
Alarm
Severity
Yellow
(minor)
Yellow
(minor)
Red (major)
125