SRX 210 Services Gateway Power
Guidelines, Requirements, and
Specifications

SRX 210 Services Gateway Site Electrical Wiring Guidelines

Table 38: Site Electrical Wiring Guidelines for the Services Gateway
Site Wiring Factor
Signaling Limitations
Radio Frequency
Interference (RFI)
This section includes the following topics:
SRX 210 Services Gateway Site Electrical Wiring Guidelines on page 157
SRX 210 Services Gateway Power Specifications and Requirements on page 158
Table 38 on page 157 describes the factors you must consider while planning the
electrical wiring for the services gateway at your site.
CAUTION: It is particularly important to provide a properly grounded and shielded
environment and to use electrical surge-suppression devices.
Guideline
To ensure that signaling functions optimally:
Install wires correctly.
Improperly installed wires can emit radio interference.
Do not exceed the recommended distances or pass wires between buildings.
The potential for damage from lightning strikes increases if wires exceed recommended
distances or if wires pass between buildings.
Shield all conductors.
The electromagnetic pulse (EMP) caused by lightning can damage unshielded conductors
and destroy electronic devices.
To reduce or eliminate the emission of RFI from your site wiring:
Use twisted-pair cable with a good distribution of grounding conductors.
Use a high-quality twisted-pair cable with one ground conductor for each data signal when
applicable, if you must exceed the recommended distances.
SRX 210 Services Gateway Site Electrical Wiring Guidelines