To maintain proper airflow through the services gateway, a blank faceplate covers
the Mini-Physical Interface Module (Mini-PIM) slot if it does not contain a Mini-PIM.
Do not remove a blank faceplate unless you are installing a Mini-PIM in the empty
slot.
NOTE: The Mini-PIMs available on the SRX 210 services gateway are not
hot-swappable. You need to power off the device before removing or installing
Mini-PIMs.
To remove a blank faceplate from an SRX 210 services gateway:
1.
2.
3.
4.
116

Removing a Blank Mini-Physical Interface Module Faceplate from the SRX 210 Services Gateway

Flat-blade screw-blade screwdriver, approximately 1/8 in. (3 mm)
Phillips (+) screwdrivers, number–1 and number–2
Removing a Blank Mini-Physical Interface Module Faceplate from the SRX 210
Services Gateway on page 116
Removing a Mini-Physical Interface Module from the SRX 210 Services
Gateway on page 117
Installing a Mini-Physical Interface Module in the SRX 210 Services
Gateway on page 118
Maintaining the SRX 210 Services Gateway Power Supply on page 114
Attach an ESD grounding strap to your bare wrist, and connect the strap to the
ESD point on the device.
If the device is powered on, power off the device. Verify that the Power LED is
off.
Loosen the screws on each side of the faceplate.
On faceplates with handles, use a 1/8 in. flat-tip screwdriver to loosen but
not remove the captive screws.
On faceplates without handles, use a number–1 phillips screwdriver to
remove the noncaptive screws.