xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To save the current configuration to the bootup configuration file:
DGS-3620-28SC:admin#save
Command: save
Saving all configurations to NV-RAM.......... Done.
DGS-3620-28SC:admin#
To save the current configuration to destination file, named 1:
DGS-3620-28SC:admin#save config 1
Command: save config 1
Saving all configurations to NV-RAM.......... Done.
DGS-3620-28SC:admin#
To save a log to NV-RAM:
DGS-3620-28SC:admin#save log
Command: save log
Saving all system logs to NV-RAM............. Done.
DGS-3620-28SC:admin#
To save all the configurations and logs to NV-RAM:
DGS-3620-28SC:admin#save all
Command: save all
Saving
configuration and logs to NV-RAM...... Done.
DGS-3620-28SC:admin#
2-21
reboot
Description
This command is used to restart the switch.
Format
reboot {force_agree}