Port Redundancy Configuration Examples - Avaya G250 Administration

Media gateway
Hide thumbs Also See for G250:
Table of Contents

Advertisement

Port redundancy configuration examples

This section provides port redundancy configuration examples.
The following example creates a port redundancy pair:
G350-003(super)# set port redundancy 6/3 6/5 on 1
Monitor: Port 6/5 is redundant to port 6/3.
Port redundancy is active - entry is effective immediately
The following example deletes a port redundancy pair:
G350-003(super)# set port redundancy 6/3 6/5 off
Entry Monitor removed: Port 6/5 is not redundant to port 6/3.
The following example enables all configured port redundancies:
G350-003(super)# set port redundancy enable
All redundancy schemes are now enabled
The following example disables all configured port redundancies:
G350-003(super)# set port redundancy disable
All redundancy schemes are disabled but not removed
The following example configures the switchback interval for all configured port redundancies:
G350-003(super)# set port redundancy-intervals 60 30
Done!
The following example displays port redundancy information:
G350-003(super)# show port redundancy
Redundancy Name
-----------------
Monitor
Minimum Time between Switchovers: 60
Switchback interval: 30
Primary Port
--------------
6/3
Configuring port redundancy (G350 only)
Secondary Port
----------------
6/5
Status
--------
primary
Issue 1.1 June 2005