The following example creates an RMON event entry:
G350-003(super)# rmon event 32 log description "Change of device" owner root
event 32 was created successfully
The following example creates an RMON history entry with an index of 80 on port 24 of the
module in slot 6, recording activity over 60 intervals (buckets) of 20 seconds each.
G350-003(super)# rmon history 80 6/24 interval 20 buckets 60 owner root
history index 80 was created successfully
The following example displays information about an RMON alarm entry:
G350-003(super)# show rmon alarm 1
alarm
alarm 1 is active, owned by root
Monitors ifEntry.1.16777216 every 20 seconds
Taking delta samples, last value was 0
Rising threshold is 10000, assigned to event # 32
Falling threshold is 1000, assigned to event # 32
On startup enable rising or_falling alarms
The following example displays information about an RMON event entry:
G350-003(super)# show rmon event 32
event
Event 32 is active, owned by root
Description is Change of device
Event firing causes log,last fired 12:36:04
The following example displays information about an RMON history entry:
G350-003(super)# show rmon history 80
history
Entry 80 is active, owned by root
Monitors the port 6/24 every 20 seconds
Requested # of time intervals, ie buckets, is 60
Granted # of time intervals, ie buckets, is 60
Sample # 2 began measuring at 0:21:16
Received 4081 octets, 41 packets,
0 broadcast and 10 multicast packets,
0 undersize and 0 oversize packets,
0 fragments and 0 jabbers,
0 CRC alignment errors and 0 collisions,
# of dropped packet events (due to a lack of resources): 0
Network utilization is estimated at 0