To configure the test plug to register:
1. Use the cna-testplug command to enter the test plug context. For example:
G350-003# cna-testplug 1
G350-003(cna-testplug 1)#
2. Use the scheduler command to configure one or more CNA scheduler IP addresses. You
can configure up to five scheduler addresses. The test plug attempts to register with a
scheduler according to its place on the list. By default, no schedulers are configured. At
least one scheduler must be configured for registration to be possible.
3. Perform the following configurations as necessary:
Use the control-port command to configure the control port. The default control port
number is 8889.
Use the rtp-echo-port command to configure the RTP echo port. The default RTP
echo port number is 8888.
Use the rtp-test-port command to configure the RTP test port. The default RTP test
port number is 8887.
Use the test-rate-limit command to configure the CNA test rate limiter. The
default test rate is 60 tests every 10 seconds.
4. If necessary, use the no shutdown command to enable the test plug. By default, the test
plug is enabled.
5. When the test plug configurations are complete, use the exit command to exit the test
plug context. From the general context, you can use the show cna testplug command
to display the test plug configuration.
6. From the general context, use the cna-testplug-service command to enable the test
plug service. For example:
G350-003# cna-testplug-service
The Converged Network Analyzer test plug is enabled.
Note:
The cna-testplug-service command requires admin access level access.
Note:
The test plug attempts to register with the first scheduler on the scheduler list. You can use
the show cna testplug command to see if the test plug is registered and to view test
plug statistics counters.

CNA test plug configuration example

The following example includes displaying default test plug configuration, configuring the test
plug, enabling the test plug service, and displaying test plug configuration and counters.
Configuring and monitoring CNA test plugs