III. Configuration procedure
1)
Configure the security cooperation router
# Set the portal service type to portal+.
<3Com> system-view
[3Com] portal service-type plus
# Configure information on the portal server, setting its name to newp, IP address to
10.110.91.146, key to huawei, port number to 50100, and URL to
/portal.
[3Com] portal server newp ip 10.110.91.146 key huawei port 50100 url
http://10.110.91.146 /portal
# Set the portal operating mode to direct authentication.
[3Com] portal method direct
[3Com] portal auth-network 172.21.0.0 255.255.0.0 ethernet 0/0/0
# Configure IP addresses of update resources.
[3Com] portal update-resource ip 10.22.1.1
[3Com] portal update-resource ip 10.22.2.1
# Configure the update-resource ID and all-resource ID.
[3Com] portal update-resource-id 10
[3Com] portal all-resource-id 20
# Assign an IP address to interface Ethernet 0/0/1.
[3Com] interface ethernet0/0/1
[3Com-ethernet0/0/1] ip address 10.110.91.1 255.255.255.0
[3Com-ethernet0/0/1] quit
# Enable portal authentication on interface Ethernet 0/0/0 and configure the IP address
of the interface connected to the CAMS server.
[3Com] interface ethernet0/0/0
[3Com-ethernet0/0/0] ip address 172.21.1.1 255.255.0.0
[3Com-ethernet0/0/0] portal upload-ip 10.110.91.1
[3Com-ethernet0/0/0] portal newp
[3Com-ethernet0/0/0] quit
# Configure interface Ethernet 1/0/0.
[3Com] interface ethernet1/0/0
[3Com-ethernet1/0/0] ip address 10.22.2.10 255.255.255.0
[3Com-ethernet1/0/0] quit
# Create a RADIUS scheme.
[3Com] radius scheme system
# Set the server type to portal.
3Com Corporation